Operating Temperature -40°C~125°C
Published 2012
Series MLH
Feature Amplified Output, Temperature Compensated
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Applications Industrial Automation
Additional Feature IP 65, REVERSE VOLTAGE PROTECTION
Voltage - Supply 5V~6V
Reach Compliance Code unknown
Output 0.5 V ~ 4.5 V
Termination Style Packard Metripak 150
Output Voltage 4V
Output Type Analog Voltage
Operating Supply Voltage 5V
Nominal Supply Current 4mA
Max Supply Current 8mA
Accuracy ±0.25%
Response Time 2 ms
Operating Pressure 300PSI (2068.43kPa)
Pressure Type Sealed Gauge
Port Style Threaded
Port Size Male -M12 x 1.5
Maximum Pressure 900PSI (6205.28kPa)
Sensors/Transducers Type PRESSURE SENSOR,STRAIN GUAGE
Housing PLASTIC
Max Pressure 900 PSI
Pressure Sensing Mode GAGE