Operating Temperature -40°C~70°C With Derating
Series iMP? (1158W)
Size / Dimension 10.00Lx5.00W x 2.50 H 254.0mmx127.0mmx63.5mm
Feature Adjustable Output, I2C Interface, PFC, PMBus?, Remote Sense, Universal Input
Part Status Active
Moisture Sensitivity Level (MSL) Not Applicable
Type Enclosed
Applications ITE (Commercial), Medical
Power (Watts) 795W
Number of Outputs 4
Approval Agency CB, CE, CSA, UL
Efficiency 85%
Voltage - Isolation 2kV
Voltage - Output 1 5V
Current - Output (Max) 35A 14A 14A 3.7A
Voltage - Input 85V~264VAC 120V~300VDC
Voltage - Output 2 15V
Voltage - Output 4 54V
Minimum Load Required No