Number of Positions 3
Max Operating Temperature 85°C
Min Operating Temperature -25°C
Gender Male
Voltage - Rated 250V
Capacitance 100nF
Voltage - Rated DC 250V
MIL Conformance NO
DIN Conformance NO
IEC Conformance YES
Option GENERAL PURPOSE
Total Number of Contacts 3
Ingress Protection IP40
Depth 57.6mm
Current Rating 10A
Approval Agency cULus, ENEC
Mating Information MULTIPLE MATING PARTS AVAILABLE
Panel Cutout Dimensions Rectangular - 30.40mm x 34.40mm
Inductance 300 μH
Max Voltage Rating (AC) 250V
Coupling Type SNAP
Connector Style IEC 320-C14
Current 10A
Throw Configuration DPST
Voltage - UL 125VAC
Voltage - IEC 250VAC
Filter Type Filtered (EMI, RFI) - Commercial, Medical
Accomodates a Fuse No
Switch Features Switch On-Off
Packaging Bulk
Series DC22
Feature Shielded
Part Status Active
Moisture Sensitivity Level (MSL) Vendor Undefined
Termination Solder
ECCN Code EAR99
Connector Type Receptacle, Male Blades - Module