Operating Temperature -50°C~70°C
Packaging Bulk
Published 2003
Series HC
Pbfree Code yes
Part Status Obsolete
Moisture Sensitivity Level (MSL) Not Applicable
Termination Plug
ECCN Code EAR99
Additional Feature COIL OPERATE VOLTAGE(AC): 176 V, COIL RELEASE VOLTAGE(AC): 66 V
Packing Method BOX
Reference Standard CSA; UL; VDE
Termination Style Plug In
Body Length or Diameter 27.2mm
Max Voltage Rating (AC) 250V
Max Current Rating 7A
Throw Configuration DPDT
Contact Form DPDT (2 Form C)
Relay Type General Purpose
Contact Current(AC)-Max 7A
Contact (AC) Max Rating R Load 7A@250VAC
Operate Time 10ms
Coil Voltage 200VAC
Coil Type Non Latching
Switching Voltage 250VAC -Max
Coil Current 6mA
Release Time 20 ms
Must Operate Voltage 160VAC
Coil Power 1.2W
Must Release Voltage 60VAC
Contact/Output Supply Type AC
Relay Action MOMENTARY
Coil/Input Supply Type AC
Coil Voltage (AC) 200V