Operating Temperature -40°C~150°C
Packaging Tube
Published 2016
Series Triaxis?
Part Status Active
Moisture Sensitivity Level (MSL) 3 (168 Hours)
Voltage - Supply 4.5V~5.5V
Peak Reflow Temperature (Cel) NOT SPECIFIED
Frequency DC~90kHz
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Output Ratiometric, Voltage or PWM (Selectable)
Operating Supply Voltage 5.5V
Number of Channels 1
Analog IC - Other Type ANALOG CIRCUIT
Polarization Bidirectional
Nominal Supply Current 12mA
Output Current 2mA
Max Supply Current 12mA
Accuracy ±1%
Response Time 8μs
Sensor Type Hall Effect, Open Loop
Linearity ±0.5%
Sensitivity 270mV/mT
For Measuring AC/DC
Current - Sensing 25mT